Watlow Series 945, 1/4 DIN Microprocessor-BasedAuto-tunin Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czujniki Watlow Series 945, 1/4 DIN Microprocessor-BasedAuto-tunin. Watlow Series 945, 1/4 DIN Microprocessor-BasedAuto-tuning Control User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 44
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
TOTAL
3 Year Warranty
CUSTOMER
SATISFACTION
Series 945
Users Manual
Watlow Controls
1241 Bundy Blvd., P.O. Box 5580, Winona, Minnesota USA 55987-5580, Phone: 507/454-5300, Fax: 507/452-4507
0600-0017-0000 Rev A
August, 1994
Supersedes without change: W945-MA40-9432
$10.00
Made in the U.S.A.
Recycled Paper At Least 10% Postconsumer Waste
1/4 DIN
Microprocessor-Based
Auto-tuning Control
Przeglądanie stron 0
1 2 3 4 5 6 ... 43 44

Podsumowanie treści

Strona 1 - Series 945

TOTAL3 Year WarrantyCUSTOMERSATISFACTIONSeries 945User’s Manual Watlow Controls1241 Bundy Blvd., P.O. Box 5580, Winona, Minnesota USA 55987-55

Strona 2 - Contents

Install and Wire, Chapter 210 WATLOW Series 945 User's ManualAlarm/RetransmitMechanical Relay, 6 Amp, Form A or B/0 - 5VDC RetransmitFigur

Strona 3 - The Watlow Series 945

Install and Wire, Chapter 211 WATLOW Series 945 User's ManualWiring ExampleWARNING:All wiring and fusing must conform to the National Electric Co

Strona 4 - Chapter 2

Keys and Displays, Chapter 312WATLOW Series 945 User's ManualKeys/DisplaysAfter 1 minute with no key activations, the control reverts to the proc

Strona 5 - Power Wiring

Setup, Chapter 413WATLOW Series 945 User's ManualSetupChapter 4How To Setup The Series 945Setting up the Series 945 is a simple process. First c

Strona 6 - Input Wiring

Setup, Chapter 414WATLOW Series 945 User's ManualSetup MenuFigure 31 -The Setup Menu NOTE:The rL and rHparameters are usedto scale the disp

Strona 7 - Output 1 Wiring

Setup, Chapter 415WATLOW Series 945 User's ManualSetupInrSPdECC _ FrLrHOt1HYS1Ot2HYS2Input: Selects the sensor input type. Only those input typ

Strona 8 - Output 1 & 2 Wiring

Setup, Chapter 416WATLOW Series 945 User's ManualSetupAL1Alarm 1: Determines whether the alarm type for Alarm 1 is process, deviation, ornone.

Strona 9 - Output 2 & Alarms

Setup, Chapter 417WATLOW Series 945 User's ManualSetupSetup MenuUse this page as a master copy for configuring your Series 945.Do not enter any v

Strona 10 - Alarm/Retransmit

Setup, Chapter 418WATLOW Series 945 User's ManualOperationFigure 32 -The Operation Menu NOTE:The upper display willalways return to theproce

Strona 11 - CAUTION:

Setup, Chapter 419WATLOW Series 945 User's ManualOperationReset/Integral1: A reset (integral) control action for Output 1 or Output 2 automati-c

Strona 12 - Chapter 3

Starting OutHow to Use the Manual2WATLOW Series 945 User's ManualContentsNotesInformational notes alert you to important details. Whenyou see a

Strona 13 - How To Setup The Series 945

Setup, Chapter 420WATLOW Series 945 User's ManualOperationOperation MenuUse this page as a master copy for your Series 945 Operation parameters.D

Strona 14 - Setup Menu

Tuning and Operating, Chapter 5WATLOW Series 945 User's Manual 21TuningIn order for the 945 to successfully complete auto-tune, the process must

Strona 15 - Setup, Chapter 4

Tuning and Operating, Chapter 522WATLOW Series 945 User's ManualTuningTo start auto-tuning:1. Press the MODE key until the AUt parameter appears

Strona 16

Tuning and Operating, Chapter 5WATLOW Series 945 User's Manual 23Manual and Automatic OperationTo change from manual to auto operation, press AUT

Strona 17

Tuning and Operating, Chapter 524WATLOW Series 945 User's ManualAlarm OutputsFigure 34 -Alarms JumperLocation. NOTE:Depending on theunit you or

Strona 18 - Auto-tune

Tuning and Operating, Chapter 5WATLOW Series 945 User's Manual 25AlarmsUsing AlarmsThe Series 945 has two alarm types, Process or Deviation. A P

Strona 19 - Operation

Tuning and Operating, Chapter 526WATLOW Series 945 User's Manual NOTE:An alarm display willbe masked by anerror condition orwhen the control is

Strona 20

Tuning and Operating, Chapter 5WATLOW Series 945 User's Manual 27Error Code Actions• Error codes Er 1, Er 2, Er 3, Er 6, or Er 7 will result in t

Strona 21 - How to Tune and Operate

WATLOW Series 945 User's ManualAppendix28Noise GuidelinesAppendix 1Noise and Installation GuidelinesFor wiring guidelines, refer to the IEEE Stan

Strona 22 - NOTE:

AppendixWATLOW Series 945 User's Manual29• Twisted pair wire should be used any time control circuit signals must travel overtwo feet, or when th

Strona 23 - Tuning/Operation

Starting OutGetting Started, Chapter 13WATLOW Series 945 User's ManualStarting OutChapter 1The Watlow Series 945,A Microprocessor-Based ControlFi

Strona 24 - Alarm Outputs

WATLOW Series 945 User's ManualAppendix30Wiring Guide• "Islatrols" and other similar power line filters are designed to carry the power

Strona 25 - Using Alarms

AppendixWATLOW Series 945 User's Manual31Noise GuidelinesLine Filtering Configurations For ControlsThese three diagrams show filter configuration

Strona 26 - Error Codes

Appendix32WATLOW Series 945 User's ManualAppendix 2CalibrationBefore attempting to calibrate, make sure you have the properequipment called for i

Strona 27

Appendix33WATLOW Series 945 User's ManualUpon entering the calibration menu, the top display window indicates CAL. Theupper display continues to

Strona 28 - Appendix 1

Appendix34WATLOW Series 945 User's ManualCalibrationCalibration MenuFigure 41 -Calibration MenuCALtCLtCHtCrLOrHIO U5 U4 A20A4tYPO4LOO4HIO1LOO1

Strona 29 - Eliminating Noise

Appendix35WATLOW Series 945 User's ManualT/C and RTDCalibration NOTEBefore calibrationon an installedcontrol, make sureall data andparameters are

Strona 30 - Wiring Guide

Appendix36WATLOW Series 945 User's Manual0-5V/4-20mA Input NOTE:Before calibration onan installed control,make sure all dataand parameters aredo

Strona 31 - Noise Guidelines

Appendix37WATLOW Series 945 User's Manual IMPORTANT:When the MANUALLED is ON the unit isautomaticallycalibrating. Yoursequence is VERYimportan

Strona 32 - Calibration

Appendix38WATLOW Series 945 User's Manual0-5V/4-20mA Retransmit IMPORTANT:When the MANUALLED is ON the unit isautomaticallycalibrating. Yourse

Strona 33

WATLOW Series 945 User's ManualAppendix39Alarm: A condition, generated by a controller,indicating that the process has exceeded or droppedbelow

Strona 34

Install and Wire, Chapter 24WATLOW Series 945 User's Manual1. Make a panel cutout per the dimensions given below. Your panel thickness canbe fro

Strona 35 - IMPORTANT:

40WATLOW Series 945 User's ManualAppendixGlossary, D-PSet point: Intended value of the process variable.Switching sensitivity: In ON/OFF contro

Strona 36 - 0-5V/4-20mA Input

Appendix41WATLOW Series 945 User's ManualIndexAAlarms, 25Jumper Selection, 24Parameter, 19Wiring, 9Appendix, 26AUTO/MAN key, 12Automatic Operatio

Strona 37 - IMPORTANT:

Appendix42WATLOW Series 945 User's ManualSpecificationsSecondary Output (Heat, Cool or None)• Solid state relay, Form A, 0.5A @ 24VAC min., 264VA

Strona 38 - 0-5V/4-20mA Retransmit

Appendix43WATLOW Series 945 User's Manual1/4 DIN, single input, dual outputdual alarms, dual digital displays.Inputs Type1 = Type J, K, T, N, C,

Strona 39 - Glossary, A-J

Appendix44WATLOW Series 945 User's ManualWatlow Series 945 User's ManualWatlow Controls, 1241 Bundy Blvd., Winona, MN 55987, 507/454-5300, F

Strona 40 - Glossary, O-Z

Install and Wire, Chapter 25 WATLOW Series 945 User's ManualPower WiringHow to Wire the Series 945The Series 945 wiring is illustrated by model n

Strona 41 - Appendix

Install and Wire, Chapter 26 WATLOW Series 945 User's ManualThermocouple InputInput WiringFigure 7 -ThermocoupleInput Wiring+-79456456Jump

Strona 42 - Specifications

Install and Wire, Chapter 27 WATLOW Series 945 User's ManualOutput 1 - Solid State Relay With Contact SuppressionOutput 1 WiringMechanical Relay,

Strona 43 - Warranty

Install and Wire, Chapter 28 WATLOW Series 945 User's ManualOutput 1 & 2 WiringOutput 1 - Process, 0 - 5VDCN.O.COM.External LoadFuseL1

Strona 44

Install and Wire, Chapter 29 WATLOW Series 945 User's ManualOutput 2 & AlarmsOutput 2 - Mechanical Relay, 6 Amp, Form AFigure 19 -6 Amp Mecha

Komentarze do niniejszej Instrukcji

Brak uwag