Watlow DIN-A-MITE Style C Instrukcja Użytkownika Strona 13

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 22
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 12
WATLOW DIN-A-MITE Style C User's Manual
13
Fan-Cooled
ç
Ó
1
Ó
3
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Gain
Bias
Open
Heater
Limit
+
-
+
-
+
-
A
LM
ALM
CT1
C
T1
C
T2
CT2
CT3
C
T3
Adjustment
Potentiometers
S
ignal Alarm
4 5 6
1 2 3
Z
one
1
Zone 
2
Zone
3
ALM = Alarm
CT = Current Transformer
T1
T2
T3
Heater
Current
Transformers (CT)
CT
black
white
white
black
white
Neutral
3-phase, 3-leg Alarm, Shorted SCR and Open Heater Alarm
ç
NOTE:
Adjust the potentiometer
clockwise to increase the
current; counterclockwise to
decrease the current.
Ó
1
WARNING:
Use National Electric (NEC)
or other country-specific
standard wiring practices to
install and operate the DIN-
A-MITE. Failure to do so
may result in damage to
equipment and property,
and/or injury or loss of life.
Ó
3
WARNING:
Only authorized and
qualified personnel should
be allowed to install and
perform preventive and
corrective maintenance on
this unit. Failure to follow
this guideline could result in
damage to equipment, and
personal injury or death.
NOTE:
The shorted SCR alarm
option is not available with
phase angle units.
Torque Guidelines
Properly torque line and
load terminals to 2.7 Nm (24
in-lb).
Retorque after 48 hours to
minimize wire cold flow.
Retorque line and load
terminals every 3 to 6
months.
ç
Ó
1
Ó
3
3-phase, 2-leg Shorted SCR Alarm
(Model DC2 _ - _ _ [C, F, K, S] _ - S _ _ _ )
(Model DC3 _ - _ _ _ _ - [S, H] _ _ _ )
T1
T2
T3
7
8
9
10
11
12
13
1
4
15
1
6
17
1
8
19
2
0
G
ain
B
ias
O
pen
Heater
L
imit
+
-
+
-
+
-
ALM
ALM
C
T1
C
T1
CT2
C
T2
CT3
CT3
A
djustment
P
otentiometers
S
ignal Alarm
4
5 6
1 2 3
Z
one
1
Zone 
2
Zone
3
ALM = Alarm
C
T = Current Transformer
Heater
Fan power required
24VÎ (dc)
120V~ (ac) 
240V~ (ac) 
(customer supplied)
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1 2 3
4 5 6
Signal Alarm
Gain
Bias
Open
Heater
Limit
+
-
CT1
CT1
Adjustment
Potentiometers
Zone
1
Zone 
2
Zone
3
L1
L2
L1
L2
Phase to neutral
100VÅ (ac)
and above
Phase to phase
200VÅ (ac)
and above
24VÎ (dc)
Red wire (+)
Black wire (-)
ç
Ó
1
Ó
3
Shorted SCR Alarm Only
NOTE:
Cooling fan terminals:
Quick connect 1/8" push on,
#16-14 AWG
Amp part no. 640929-1 or
equivalent
4
5
6
15
16
Current
Transformer (CT)
Neutral
T
3
T2
T
1
Przeglądanie stron 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 21 22

Komentarze do niniejszej Instrukcji

Brak uwag