SpecView from WATLOW
Addendum to SpecView Manual
HMI Software
1241 Bundy Boulevard, Winona, Minnesota USA 55987
Phone: +1 (507) 454-5300, Fax: +1 (507) 452-4507
http://www.watlow.com
0600-0056-0015 Rev.H ©2013 Watlow. All rights reserved.
March 2013
Przeglądanie stron 0
1 2 3 4 5 6 ... 39 40

Podsumowanie treści

Strona 1 - HMI Software

SpecView from WATLOW Addendum to SpecView Manual HMI Software 1241 Bundy Boulevard, Winona, Minnesota USA 55987 Phone: +1 (507) 454-5300, F

Strona 2 - Table of Contents

SpecView from Watlow  10  Watlow Addendum Model For part numbers matching… Add… Instrument Name (Description) Address String Named1 RMS RMSx-xxx

Strona 3 - Chapter 1: Introduction

SpecView from Watlow  11  Watlow Addendum Model For part numbers matching… Add… Instrument Name (Description) Address String Named1 ST STxx-xxxx

Strona 4 - Naming Instruments

SpecView from Watlow  12  Watlow Addendum Decimal Places Specify zero (0) to display whole numbers for parameters such as process variable and s

Strona 5

SpecView from Watlow  13  Watlow Addendum Register Addresses for EZ-ZONE Express Controller Instrument First Instance Address* EZ-ZONE Alarm 14

Strona 6

SpecView from Watlow  14  Watlow Addendum Register Addresses and Offsets for EZ-ZONE RML Modules Instrument Instances First Instance Address In

Strona 7

SpecView from Watlow  15  Watlow Addendum Old EZ-ZONE Modbus Instruments The following instruments are included in the Watlow Modbus driver, but

Strona 8

SpecView from Watlow  16  Watlow Addendum Chapter 3: Setup Procedures The following sections provide procedures for establishing communications

Strona 9

SpecView from Watlow  17  Watlow Addendum 8) For the Port to which the controllers are attached, choose the appropriate protocol driver in Prot

Strona 10

SpecView from Watlow  18  Watlow Addendum 10) If another protocol must be scanned, click Cancel and repeat this procedure from step 8 for the n

Strona 11

SpecView from Watlow  19  Watlow Addendum Manually Set up or Modify an EZ-ZONE Standard Bus Network The following procedures guide you through

Strona 12

SpecView from Watlow  2  Watlow Addendum Table of Contents Chapter 1: Introduction ...

Strona 13 - -ZONE RME Modules

SpecView from Watlow  20  Watlow Addendum To add one or more instruments to a configuration: 1) Open the Graphical Display Window in the config

Strona 14

SpecView from Watlow  21  Watlow Addendum 7) In the Add/Rename Instrument dialog type a Name for the instrument. 8) Select the Port. 9) Enter

Strona 15

SpecView from Watlow  22  Watlow Addendum 15) To save the GDW: • From the File menu, choose Save As. • Enter a File name for the GDW. • Clic

Strona 16 - Chapter 3: Setup Procedures

SpecView from Watlow  23  Watlow Addendum 4) Enter a name for the configuration. 5) Click OK. To add one or more instruments to a configurat

Strona 17

SpecView from Watlow  24  Watlow Addendum For This Controller… From this Protocol Driver… Add These Instruments… With Address String… 986, 987,

Strona 18

SpecView from Watlow  25  Watlow Addendum 11) The first time you add an instrument on a port, SpecView opens the Port Settings Dialog. When thi

Strona 19 - Network

SpecView from Watlow  26  Watlow Addendum Manually Set up or Modify an EZ-ZONE Modbus TCP Network The following procedures guide you through th

Strona 20

SpecView from Watlow  27  Watlow Addendum 3) Click Show New. 4) In the Variables list click the button next to Watlow Modbus. 5) Select the

Strona 21

SpecView from Watlow  28  Watlow Addendum 10) Repeat steps 5 to 9 as needed to add additional instruments. 11) Click Show Defined. 12) To add

Strona 22

SpecView from Watlow  29  Watlow Addendum Rename an Instrument In order to more easily correlate items in SpecView’s Graphical Display Windows (

Strona 23

SpecView from Watlow  3  Watlow Addendum Chapter 1: Introduction SpecView is a powerful and easy-to-use Human Machine Interface software package

Strona 24

SpecView from Watlow  30  Watlow Addendum To replace an instrument view: 1) Delete the instrument view to be replaced: • Select the instrumen

Strona 25

SpecView from Watlow  31  Watlow Addendum Adjust the Displayed Decimals The following procedures describe how to adjust the number of decimal pl

Strona 26

SpecView from Watlow  32  Watlow Addendum 2) With SpecView running, to enter the configuration mode, from the File menu choose Configuration Mo

Strona 27

SpecView from Watlow  33  Watlow Addendum Chapter 4: Feature Reference This chapter describes the instruments and instrument views supporting Wa

Strona 28

SpecView from Watlow  34  Watlow Addendum Integrated Limit, Stand Alone and RM Limit and PM Express Limit_ Auxiliary Input Single Current Inp

Strona 29 - Rename an Instrument

SpecView from Watlow  35  Watlow Addendum EZ-ZONE RM Standard Bus Instruments EZ-ZONE RM control systems are supported by a wide variety of inst

Strona 30

SpecView from Watlow  36  Watlow Addendum Single Current Input RMC Profile Operation Digital I/O EZ-ZONE ST Standard Bus Instruments The EZ-Z

Strona 31

SpecView from Watlow  37  Watlow Addendum EZ-ZONE Modbus Instruments Watlow recommends using Standard Bus communications between SpecView and EZ

Strona 32

SpecView from Watlow  38  Watlow Addendum EZ-ZONE Profile Operation Profile State Profile Start Profile Action Request Active Step Current File

Strona 33 - Chapter 4: Feature Reference

SpecView from Watlow  39  Watlow Addendum EZ-ZONE Profile (ST Map 1) This instrument includes the listed parameters for each of the ten steps in

Strona 34

SpecView from Watlow  4  Watlow Addendum There are several protocol drivers that support Watlow products. The table below lists these protocol d

Strona 35

How to Reach UsCorporate HeadquartersWatlow Electric Manufacturing Company12001 Lackland RoadSt. Louis, MO 63146Sales: 1-800-WATLOW2Manufacturing Supp

Strona 36

SpecView from Watlow  5  Watlow Addendum • Indicates the controller’s location in the panel • Includes network information such as port and ad

Strona 37 - EZ-ZONE Modbus Instruments

SpecView from Watlow  6  Watlow Addendum Model For part numbers matching… Add… Instrument Name (Description) Address String Named1 PM PMxxxxx-xx

Strona 38

SpecView from Watlow  7  Watlow Addendum Model For part numbers matching… Add… Instrument Name (Description) Address String Named1 RMC (cont.) R

Strona 39

SpecView from Watlow  8  Watlow Addendum Model For part numbers matching… Add… Instrument Name (Description) Address String Named1 RME RMEx-xxxx

Strona 40 - How to Reach Us