WATLOW Series 922 User's Manual
Appendix
Specifications
Specifications
Control Mode
Microprocessor-based, user selectable modes.
Dual inputs, dual control outputs per channel.
8 event outputs/1 event input/1 remote hold input.
99 step programmer with up to 10 profiles.
Control outputs: User selectable as: Heat/Cool, Cool/Heat.
Outputs independent, or related via deadband for Heat/Cool.
ON/OFF: 3°F or 1.7°C switching hysteresis or 0.3°F or 0.17°C for 0.1°
Units .
PID parameters per channel:
Proportional band: 0 to 500°C or 0 to 50.0°C for 0.1° Units.
Reset: 0.00 to 5.00 repeats per minute.
Rate: 0.00 to 5.00 minutes.
Rate band: 0 to 7 times proportional band.
Cycle time: 1 to 60 seconds.
Deadband: ±36°F, ±20° C or Units ± 2.0°C for 0.1° Units.
Auxiliary outputs: User selectable as:
Events 1 & 2 selectable as alarms for Channels 1 & 2.
Process or deviation value, per output.
Alarms, latching or non-latching. When non-latching, control will have
3°F/1.7°C switching hysteresis or 0.3°F/0.17°C for 0.1° Units.
Separate high and low values, per output.
Operator Interface
Membrane front panel.
Four digit 1/2" LEDs displaying actual process input value.
LED indication of °C, °F, or process variable units.
MODE, ENTER, UP, DOWN, and RUN/HOLD keys.
Eight character alphanumeric display of operating data.
Input
Thermocouple, RTD and electrical process input.
Automatic cold junction compensation for thermocouple.
RTD input 2 or 3 wire, platinum, 100 ohm @ 0°C, calibrated to JIS curve
#3916 (0.003916 //°C), DIN curve #3850 (0.003850 //°C).
Sensor break protection de-energizes control outputs to protect system.
Ungrounded sensors required..
Operating ranges user selectable.
J t/c: 32 to 1382°F or 0 to 750°C
K t/c: -328 to 2282°F or -200 to 1250°C
T t/c: -328 to 662°F or -200 to 350°C
1° RTD: -328 to 1112°F or -200 to 600°C
0.1° RTD: -99.9 to 392.0°F or -99.9 to 200.0°C
0-5VDC: -99 to 1800 units
4-20mA: -99 to 1800 units
RH, 0-5VDC: 0 to 100% RH Vaisala sensor
Calibration offset or input signal, ±90°F, ±50°C, ±50 PVU's, front panel
adjustable 9.0°F, ±5.0°C for 0.1°C Units.
°F, °C, or process variable units are user selectable.