Strona 1 - Operator Interface Terminals

Silver Series EM Operator Interface Terminals EZwarePlus Programming Manual Operator Interface Terminals

Strona 2 - APPLICATIONS ASSISTANCE

2 EZwarePlus Programming Manual Icon Meaning  Identifies a procedure.  Indicates a reference to additional information.  Indicates an impo

Strona 3

92 EZwarePlus Programming Manual 2. The Object ID of each object will be listed. For example, WC_0 is Direct Window #0, TS_0 is Toggle Switch #0,

Strona 4

EZwarePlus Programming Manual 93  If you still don’t see the grid after you have enabled it, make sure that the color of the grid doesn’t match th

Strona 5 - Table of Contents

94 EZwarePlus Programming Manual To zoom in on the selected window 1. Use the zoom pull-down menu in the Edit Toolbar. Zoom levels range from 50%

Strona 6

EZwarePlus Programming Manual 95 To change the state of the selected window 1. Click the State pull-down menu in the State Toolbar and selec

Strona 7

96 EZwarePlus Programming Manual To select all objects 1. On the Edit Menu, click Select All Objects. 2. Small, clear, square blocks appear arou

Strona 8

EZwarePlus Programming Manual 97 3. Modify the settings according to your requirements. 4. Click OK. The main screen of EZwarePlus is redisplaye

Strona 9 - Chapter 1 – Introduction

98 EZwarePlus Programming Manual 1. From the Edit menu, select Window Process and click Window Copy... The Window Copy dialog box appears. 2. I

Strona 10 - What You Need

EZwarePlus Programming Manual 99 To resize a graphics object 1. Select the object to be resized. 2. To resize the object, move the mouse cursor

Strona 11 - OIT/HMI Basics

100 EZwarePlus Programming Manual Grouping Objects When creating graphics on a window, you may create a complex graphic that is actually composed o

Strona 12 - Windows

EZwarePlus Programming Manual 101 Use the nudge up , down , left , and right commands (Edit > Nudge or the Nudge icons in the Edit tool

Strona 13 - List of Features

EZwarePlus Programming Manual 3 OIT/HMI Basics Operator Interface Terminals (OITs) and Human Machine Interfaces (HMIs) provide much more versatilit

Strona 14

102 EZwarePlus Programming Manual 2. From the Edit menu, select Make Same Color. The selected objects will all change to the same color as the la

Strona 15

EZwarePlus Programming Manual 103 1. Select the object you wish to lock. 2. From the Edit menu, select Pinned or click the Pinned icon from the E

Strona 16 - Chapter 2 – HMI Local Setup

104 EZwarePlus Programming Manual Device tab settings: 1. Click the New… button. The Device Properties dialog appears.  You can “export” a proje

Strona 17 - Changing the System Settings

EZwarePlus Programming Manual 105 Ethernet/COM port: Select whether the remote HMI will be connected using Ethernet or a serial COM port. You must

Strona 18

106 EZwarePlus Programming Manual 12. Default station no. use station no. variable: Enables using a Local Word (where LW10000-LW10015 corresponds

Strona 19

EZwarePlus Programming Manual 107 Model tab settings: 1. HMI model: Select the HMI model that you are programming. 2. HMI station no.: When mult

Strona 20

108 EZwarePlus Programming Manual 8. Pass through: select the Port Number to use in Pass-Through mode. The same setting needs to be made in the Ut

Strona 21

EZwarePlus Programming Manual 109 General tab settings: 1. Fast selection button: The Attribute: drop-down enables or disables the fast selection

Strona 22 - Viewing System Information

110 EZwarePlus Programming Manual 3. Options: The Startup window no. selects the window number that will be displayed every time the HMI is starte

Strona 23

EZwarePlus Programming Manual 111 System Setting tab settings: 1. Startup language after redownloading the project: Select the language that the

Strona 24

4 EZwarePlus Programming Manual Graphics Object A Graphics Object is any text, icon, or picture that can be displayed on the HMI. Graphics objects

Strona 25 - Adjustment)

112 EZwarePlus Programming Manual 6. Disable buzzer: When checked, the HMI will not sound the buzzer (beep) when the screen is touched. Local Bit

Strona 26

EZwarePlus Programming Manual 113 Security tab settings: The Security tab is used to set up a table of users, user levels (access classes), and pa

Strona 27

114 EZwarePlus Programming Manual The object can be configured to handle insufficient security in one of two ways: • The object can be hidden whi

Strona 28 - 1010-1015, Rev. 03

EZwarePlus Programming Manual 115 LW9222 Current access classes 16-bit binary Indicates the Access Classes currently allowed. Bit 0 indicates Class

Strona 29

116 EZwarePlus Programming Manual Font tab settings: Determines the fonts available for non-ASCII strings. If a non-ASCII character set or double-

Strona 30

EZwarePlus Programming Manual 117 Extended Memory tab settings: The Extended Memory tab is used to configure the extended memory for saving data t

Strona 31

118 EZwarePlus Programming Manual Printer/Backup Server tab settings: 1. Check the Use Remote Printer/Backup Server checkbox to enable the HMI to

Strona 32

EZwarePlus Programming Manual 119 E-Mail tab settings: The e-Mail tab is used to enable and configure the email feature in EZwarePlus. Alarms can

Strona 33

120 EZwarePlus Programming Manual SMTP settings: SMTP (Simple Mail Transfer Protocol) is an internet standard for sending email across IP networks.

Strona 34 - HMI5000P/L/HD

EZwarePlus Programming Manual 121 Recipes tab settings: There are two methods for creating and storing recipes in EZwarePlus. One method uses the

Strona 35 - Troubleshooting

EZwarePlus Programming Manual 5 The HMI5000P/L/HD Series are powered using +24VDC. A reset switch is provided on the back of the HMI to reinitializ

Strona 36 - To create Window 11:

122 EZwarePlus Programming Manual 3. Size: Defines the number of words for each element in the recipe record. Adjustable only for the ASCII, Unico

Strona 37

EZwarePlus Programming Manual 123 Reboot HMI EZwarePlus can automatically reboot the HMI after download. To enable automatic reboot of HMI after d

Strona 38 - To create a Function Key:

124 EZwarePlus Programming Manual 2. Click the Browse… button for the HMI500 EOB file and select the EasyBuilder-500 project file you wish to con

Strona 39

EZwarePlus Programming Manual 125 5. Delete “Direct Window” objects which are triggered with LB9060~9069, 9080, 9081, (HMI5000-series use a new m

Strona 40

126 EZwarePlus Programming Manual Chapter 7 – Creating Windows This section shows how to create and use windows in EZwarePlus. Window Fundamentals

Strona 41 - To create a Bar graph:

EZwarePlus Programming Manual 127 The Open Window dialog box lists all of the windows currently created for the project. An asterisk next to a Wind

Strona 42

128 EZwarePlus Programming Manual To create a new window: 1. From the Window menu, select Open Window. The Open Window dialog box appears. 2. C

Strona 43

EZwarePlus Programming Manual 129 Window Settings Let’s look more closely at the parameters you can change when creating a new window.  When a win

Strona 44 - To create a Set Word:

130 EZwarePlus Programming Manual Assigning Underlay Windows An Underlay Window is a Base Window that is displayed at the same time as the Base Win

Strona 45

EZwarePlus Programming Manual 131 • Underlay windows are always positioned from the top left corner of the screen. Any position settings you make

Strona 46

6 EZwarePlus Programming Manual Moving Shape Creates a multi-state graphic object, which changes state (picture) and position on the screen accord

Strona 47

132 EZwarePlus Programming Manual 1. From the Window menu, select Open Window. The Open Window dialog box appears. 2. Highlight the window that y

Strona 48

EZwarePlus Programming Manual 133 Calling a popup window If a function key object is created to call a popup window, the window that is displayed i

Strona 49 - To create a Bit Lamp:

134 EZwarePlus Programming Manual To call a full screen window using the PLC Control object: 1. From the Objects menu, select PLC Control. The PL

Strona 50

EZwarePlus Programming Manual 135 The PLC must only enter window numbers that represent full-size windows when using the PLC Control Object functio

Strona 51 - To create a Set Bit:

136 EZwarePlus Programming Manual 6. Click OK to return to the main screen of EZwarePlus. The mouse cursor will have a square object that represen

Strona 52

EZwarePlus Programming Manual 137 Tips and Suggestions Having trouble deciding which method to use to display a base window? Here are some suggesti

Strona 53 - Saving your first project

138 EZwarePlus Programming Manual Using the Common Window Your project might require that some data be displayed on the HMI screen at all times, re

Strona 54 - Compiling your first project

EZwarePlus Programming Manual 139 3. As you can see, some of the parameters for a common window are disabled and cannot be changed. Window #4 is a

Strona 55

140 EZwarePlus Programming Manual When Above base window is set, the result is: When Below base window is set, the result is: To set the Above/B

Strona 56

EZwarePlus Programming Manual 141 To change the active common window: 1. Create a new project. The Common Window (Window 4) is automatically cr

Strona 57

EZwarePlus Programming Manual 7 Data Transfer (Time-based) Transfers data to the specified PLC registers on a timed basis. Data Sampling Stores d

Strona 58 - Chapter 5 – Simulator Mode

142 EZwarePlus Programming Manual When the HMI initializes, it displays the startup screen (Window #10) and the default common window. To change c

Strona 59

EZwarePlus Programming Manual 143 To open a fast selection window: 1. From the Window menu, select Open Window. The Open Window dialog box appear

Strona 60 - To use EasySimulator

144 EZwarePlus Programming Manual Using the Fast Selection Button The fast selection button is used to display the Fast Selection window. Pressing

Strona 61 - Chapter 6 – Using EZwarePlus

EZwarePlus Programming Manual 145 To display the fast selection button: 1. Select Edit > System Parameters. The System Parameters Setting Dial

Strona 62

146 EZwarePlus Programming Manual System Message Windows EZwarePlus has four Windows designated as System Message windows. Window #5 is designated

Strona 63 - Utility

EZwarePlus Programming Manual 147 The amount of available memory is indicated by the following Reserved Local Words: LW9072 HMI free space availa

Strona 64

148 EZwarePlus Programming Manual Chapter 8 – Creating and Using the Tag Library and Label Library EZwarePlus includes the ability to create and u

Strona 65

EZwarePlus Programming Manual 149 5. Select the Address type (Bit or Word). 6. Select the Device type from the drop-down menu. 7. Enter the Regi

Strona 66

150 EZwarePlus Programming Manual To export the tag library to a .csv file or .xls file: 1. Click Export CSV or Export EXCEL. The Open dialog box

Strona 67

EZwarePlus Programming Manual 151 Creating the Label Library The Label library is a database of text Labels, for use with objects utilizing text la

Strona 68 - EasyPrinter

8 EZwarePlus Programming Manual Chapter 2 – HMI Local Setup Factory Configuration Each HMI arrives from the factory with a demo project file that i

Strona 69

152 EZwarePlus Programming Manual 4. Click the OK button, and the new label is added to the database. The Name will appear in a selectable listing

Strona 70

EZwarePlus Programming Manual 153 Setting Different Fonts for Different Languages If you would like to use different fonts for different languages,

Strona 71

154 EZwarePlus Programming Manual The label library can also be imported and exported using an Excel (*.xls) file format or comma-separated variabl

Strona 72

EZwarePlus Programming Manual 155 4. To use the multiple language feature of the Label Library to display object labels in languages other than th

Strona 73

156 EZwarePlus Programming Manual Chapter 9 – Creating and Using Keypads The HMI operator must have a keypad available to enter new data when usin

Strona 74

EZwarePlus Programming Manual 157 Function Description [ENTER] Configures the Function Key as an Enter key. When pressed, it will write the alphan

Strona 75 - Simulation Settings

158 EZwarePlus Programming Manual To create a sample keypad entry screen: 1. Start a New project file in EZwarePlus. 2. From the Objects menu, s

Strona 76 - Pass-through mode

EZwarePlus Programming Manual 159 Editing data registers using a keypad: 1. Save and compile the new project, then test the operation of the keyp

Strona 77

160 EZwarePlus Programming Manual Chapter 10 – Bar Graphs and Meters This chapter focuses on two special graphic objects, which can be used to dis

Strona 78

EZwarePlus Programming Manual 161 5. In the Attribute section, select how the Bar Graph is to operate. Function Option Description Type Normal Th

Strona 79 - EZwarePlus Features

EZwarePlus Programming Manual 9 Changing the System Settings To change the system settings on the HMI: 1. Open the System Setup Toolbar as descri

Strona 80

162 EZwarePlus Programming Manual 7. Set up the Target indicator. This selects the color of the filled part of the bar when it reaches a preset va

Strona 81

EZwarePlus Programming Manual 163 Creating Meter Displays The Meter Display Object is used to represent the data in a 16-bit or 32-bit PLC register

Strona 82

164 EZwarePlus Programming Manual 5. In the Degree section, you can select the range of your meter, where the range is 0 to 360. The Start degree

Strona 83

EZwarePlus Programming Manual 165 8. In the Pointer section, select arm style, color, length, and width. 9. The Pin point section allows you to a

Strona 84

166 EZwarePlus Programming Manual Chapter 11 – Data Sampling, Trend Displays, and History Data Displays Creating Data Sampling Objects and Trend Di

Strona 85

EZwarePlus Programming Manual 167 2. Click New… to create a new data sampling object. 3. Description: Enter a name for the object. This isn&apos

Strona 86

168 EZwarePlus Programming Manual 8. Click New... to call the configuration dialog. 9. Enter a Description for the data format and then select t

Strona 87

EZwarePlus Programming Manual 169 To create a Trend Display Object: 1. From the Objects menu, click Trend Display, or click the Trend Display i

Strona 88

170 EZwarePlus Programming Manual 8. Click on the Trend tab to display the Trend dialog box. 9. Select the Frame color and the Background color

Strona 89

EZwarePlus Programming Manual 171 16. In the Data sampling object section, select the channels you want to display by clicking the checkboxes und

Strona 90

10 EZwarePlus Programming Manual 8. Configure appropriate time and date settings. 9. Click on the Security tab to display the security settings

Strona 91

172 EZwarePlus Programming Manual History Data Display The History Data Display shows data captured by the Data Sampling object. Data is displayed

Strona 92

EZwarePlus Programming Manual 173 2. Data Sampling Object index: Select from drop-down list which data file to use. Data files are created using

Strona 93

174 EZwarePlus Programming Manual 7. Date: Enable to display the date when the data was captured by the Data Sampling object. a. Style: Select f

Strona 94

EZwarePlus Programming Manual 175 Data Format tab: Used to configure how the data appears for each column: 1. Channel: Channels are configured in

Strona 95 - Managing Projects

176 EZwarePlus Programming Manual Title tab: Used to configure a title bar or legend at the top of the data columns: 1. Use title: Check to use

Strona 96

EZwarePlus Programming Manual 177 Chapter 12 – Capturing Alarms and Events This chapter looks at how the HMI5000P Series uses alarms and events. U

Strona 97 - Display Options

178 EZwarePlus Programming Manual 3. On the General tab, set the Category for the alarm. The Alarm Bar, Alarm Display, and Event Display can filt

Strona 98

EZwarePlus Programming Manual 179 10. Enter the message to display when the alarm or event is triggered in the Content box. If you would like to

Strona 99

180 EZwarePlus Programming Manual 16. Select Send when event triggered to send an email when the event/alarm is triggered, and select Send when

Strona 100

EZwarePlus Programming Manual 181 21. Click OK to return to the Alarm (Event) Log dialog. You may select a location to save History files by selec

Strona 101

EZwarePlus Programming Manual 11 11. The new password must be entered, and then entered again to confirm. As the password is entered into the conf

Strona 102

182 EZwarePlus Programming Manual 4. Include categories: To include all categories, set this at 0 to 0. 5. Acknowledge style: Select either Clic

Strona 103 - Basic Editing Commands

EZwarePlus Programming Manual 183 Displaying Alarms using the Alarm Bar Object The Alarm Bar Object displays alarms scrolling horizontally along a

Strona 104

184 EZwarePlus Programming Manual 7. Select the format for how the date and time is displayed in the Date: and Time: drop-down boxes. 8. Click th

Strona 105

EZwarePlus Programming Manual 185 used to popup an acknowledgement Indirect Window. In History mode, the History control address is the register us

Strona 106

186 EZwarePlus Programming Manual 11. Use the Display order list to arrange the order in which the selected event information is displayed, and se

Strona 107

EZwarePlus Programming Manual 187 Chapter 13 – Security The security feature in EZwarePlus allows you to create up to 12 users with individual pass

Strona 108 - Nudging Objects

188 EZwarePlus Programming Manual There are two security modes in EZwarePlus, General mode and Enhanced Security mode. General mode operates the sa

Strona 109 - Making Objects the Same Size

EZwarePlus Programming Manual 189 Enhanced Security Mode When Enhanced security mode is selected, up to 11 users can be enabled along with a defaul

Strona 110

190 EZwarePlus Programming Manual The access classes can be assigned descriptions, which appear in the Object class drop-down when enabling the Use

Strona 111 - System Parameter Settings

EZwarePlus Programming Manual 191 7 Delete user account by name selected in Control Address + 4. Note: The currently logged-in user account cannot

Strona 112 - Device tab settings:

ii EZwarePlus Programming Manual COPYRIGHT NOTICE This manual is a publication of Maple Systems, Inc., and is provided for use by its customers onl

Strona 113

12 EZwarePlus Programming Manual 14. Click the Firmware setting tab to access the Upgrade firmware option and the Portrait Mode settings (for mod

Strona 114

192 EZwarePlus Programming Manual To log in from a keypad: 1. Create an ASCII Input object, addressed to ([Control Address] + 4), length 8 words,

Strona 115 - Model tab settings:

EZwarePlus Programming Manual 193 To delete a user by Option List: 1. Create an Option List with User account selected for the Source of item data

Strona 116

194 EZwarePlus Programming Manual Disable protection permanently after initial activation: This option removes the user restriction from the object

Strona 117 - General tab settings:

EZwarePlus Programming Manual 195 Hide when disabled: When this box is checked, the object is invisible on the screen until the designated bit is

Strona 118

196 EZwarePlus Programming Manual Auto logout There is an Auto logout feature in the System Parameters on the System Setting tab (Edit > System

Strona 119 - System Setting tab settings:

EZwarePlus Programming Manual 197 Project Protection Enable Project Protection in the System Parameter settings (Edit > System Parameters > G

Strona 120

198 EZwarePlus Programming Manual Disable Upload Function Activate the Disable Upload Function in the System Parameter settings (Edit > System P

Strona 121 - Security tab settings:

EZwarePlus Programming Manual 199 XOB Password A project (*.mtp) must be compiled (*.xob) before it can be downloaded to an HMI. When compiling a p

Strona 122

200 EZwarePlus Programming Manual Decompiling Prohibited Click the Decompilation is prohibited checkbox in the Compiling window to prevent the comp

Strona 123

EZwarePlus Programming Manual 201 System Passwords The System Setup Toolbar in the HMI has the option of changing several passwords from their defa

Strona 124 - Font tab settings:

EZwarePlus Programming Manual 13 Click Start VNC to enable the VNC server. Click the VNC login password to enter the password used to login to the

Strona 125

202 EZwarePlus Programming Manual To change a system password, the new password must be entered, and then entered again to confirm. As the password

Strona 126

EZwarePlus Programming Manual 203 Upload Password: The password required to upload data from the HMI to a PC or memory module. Upload to a PC usin

Strona 127 - E-Mail tab settings:

204 EZwarePlus Programming Manual Download Password: The password required to download data to the HMI from a PC or memory module. Download from

Strona 128

EZwarePlus Programming Manual 205 Upload (History) Password: The password required to upload history files from the HMI to a memory module. Uploa

Strona 129 - Recipes tab settings:

206 EZwarePlus Programming Manual Chapter 14 – Administrator Tools The Administrator Tools is a separate utility that allows storing data to a USB

Strona 130

EZwarePlus Programming Manual 207 To upload the data to the HMI, you must have a Function Key configured to import the user data. In the Function

Strona 131 - Save and Compile the Project

208 EZwarePlus Programming Manual USB Security Key  The project in the HMI must have Enhanced Security mode selected in the System Parameters >

Strona 132

EZwarePlus Programming Manual 209 To log-in the user, you must have a Function Key configured to Use [USB Security Key] to Login. In the Function

Strona 133

210 EZwarePlus Programming Manual e-Mail SMTP Server Settings Selecting e-Mail SMTP Server Settings allows the e-Mail server settings to be change

Strona 134 - Chapter 7 – Creating Windows

EZwarePlus Programming Manual 211 To update the HMI, you must have a Function Key configured to Use [USB Security Key] to Login. In the Function K

Strona 135 - Creating a New Window

14 EZwarePlus Programming Manual The Popup download window option allows you to turn on or off whether the Download dialog window appears on the s

Strona 136

212 EZwarePlus Programming Manual e-Mail Contacts Selecting e-Mail Contacts allows the e-Mail contacts in the HMI to be changed without having to

Strona 137 - Window Settings

EZwarePlus Programming Manual 213 To update the HMI, you must have a Function Key configured to Import e-mail settings and contacts. In the Funct

Strona 138 - Assigning Underlay Windows

214 EZwarePlus Programming Manual Chapter 15 – Recipes EZwarePlus supports creating and using recipes in the HMI5000P Series. EasyBuilder-5000 supp

Strona 139 - Deleting a Window

EZwarePlus Programming Manual 215 Click the “Add new recipe” button to create a new recipe in the Recipes list. Click the New button to add an it

Strona 140 - Using Base Windows

216 EZwarePlus Programming Manual When changes have been made, a popup window will ask if you want to apply the changes to the recipe database. If

Strona 141 - Using the PLC

EZwarePlus Programming Manual 217 Click the Add button to add records to the recipe. Enter the data for each column. In this example, the first co

Strona 142

218 EZwarePlus Programming Manual Create a new Numeric Input or ASCII Input object and select Recipe for the Device type.  A recipe must be create

Strona 143

EZwarePlus Programming Manual 219 Command: Performs an action on the recipe based on the value entered. 1. Add a new record. The selected record i

Strona 144

220 EZwarePlus Programming Manual The Upload from PLC and Download to PLC buttons are Data Transfer (Trigger-based) objects that transfer the recip

Strona 145

EZwarePlus Programming Manual 221 Chapter 16 – Operation Log The Operation Log is a mechanism that records operator actions to an SQLite database f

Strona 146 - Using the Common Window

EZwarePlus Programming Manual 15 Transferring Projects and Data from USB/SD Card When a USB or SD device is inserted into the HMI5000P Series, a d

Strona 147

222 EZwarePlus Programming Manual 1. Check the Enable Operation Log Function checkbox. The object list displays all objects available for recordi

Strona 148

EZwarePlus Programming Manual 223 View Settings The Operation Log View displays data recorded by the Operation Log object in a spreadsheet-like for

Strona 149

224 EZwarePlus Programming Manual 3. Profile: Specify the background color of the view. If the Transparent box is checked, the background color i

Strona 150

EZwarePlus Programming Manual 225 Title Tab The Title tab sets up which fields are displayed in the Operation Log View. 1. In the top section, en

Strona 151

226 EZwarePlus Programming Manual Chapter 17 – EasyDiagnoser and Easy Watch EasyDiagnoser is a diagnostic utility that monitors the read and write

Strona 152

EZwarePlus Programming Manual 227 Enter the IP address of the HMI that you want to monitor. EasyDiagnoser will open and attempt to connect to the

Strona 153

228 EZwarePlus Programming Manual Main Window The main window in EasyDiagnoser is where you set the parameters for monitoring the communications an

Strona 154 - System Message Windows

EZwarePlus Programming Manual 229 • The PID column is the Package ID number for the Polling Package containing the object’s address. Look for that

Strona 155

230 EZwarePlus Programming Manual The Station column lists the Station Number assigned to the Device (if applicable). When the objects within a Pol

Strona 156

EZwarePlus Programming Manual 231 Logger The Logger window show events that occur in EasyDiagnoser.  EasyDiagnoser does not support monitoring PL

Strona 157

16 EZwarePlus Programming Manual Password Enter the Download password. Download project files When checked, the HMI will check the specified fold

Strona 158 - Using the Tag Library

232 EZwarePlus Programming Manual To add an HMI to the project: 1. Open the HMI Manager by clicking on the Objects menu and selecting HMI Manager

Strona 159 - Creating the Label Library

EZwarePlus Programming Manual 233 The next step is to add address monitors in the EasyWatch window to view registers in an HMI and PLC. To add a

Strona 160

234 EZwarePlus Programming Manual 5. Select the PLC to monitor. If you want to monitor a register in the HMI, select HMI5000 Series HMI. If you wa

Strona 161

EZwarePlus Programming Manual 235 To begin monitoring data: 1. Select one or more monitor objects in the list (hold the shift key to select multi

Strona 162 - Using the Label Library

236 EZwarePlus Programming Manual 4. Select the Macro Type by clicking the Active Type button. Direct Active: The selected macro object is trigger

Strona 163

EZwarePlus Programming Manual 237 Chapter 18 – Using the Modbus Gateway The Modbus Gateway allows any ModbusTCP Master to request HMI data using s

Strona 164 - How to Create a Keypad

238 EZwarePlus Programming Manual Configuring the Modbus Gateway 1. Configure the PLC to which Modbus registers will be mapped. Refer to the Syst

Strona 165

EZwarePlus Programming Manual 239 This example will show how to use the Modbus Gateway to obtain data from an Animatics Smartmotor. 1. Click the A

Strona 166

240 EZwarePlus Programming Manual In this example, Modbus registers are being mapped to array elements in an Animatics Smartmotor controller. Descr

Strona 167

EZwarePlus Programming Manual 241 Appendix A – Reserved Local Memory EZwarePlus reserves some Local Words (LW) and Local Bits (LB) in the HMI for

Strona 168 - Creating Bar Graphs

EZwarePlus Programming Manual 17 Changing or Restoring the HMI Settings by USB or SD There may be times when it is necessary to change or update th

Strona 169

242 EZwarePlus Programming Manual Here is a list of the current system tags in EZwarePlus. As new versions of EZwarePlus are released, these may ch

Strona 170

EZwarePlus Programming Manual 243 LB-9045 : memory-map communication fails (when ON) LB-9046 : project key is different from HMI key (when ON) LB-

Strona 171 - Creating Meter Displays

244 EZwarePlus Programming Manual LB-9190 : auto. connection for PLC (USB) (when ON) LB-9191 : PLC status (USB), set on to retry connection LB-919

Strona 172

EZwarePlus Programming Manual 245 LB-9501 : PLC 2 status (SN1, COM2), set on to retry connection LB-9502 : PLC 2 status (SN2, COM2), set on to ret

Strona 173

246 EZwarePlus Programming Manual LB-11949 : delete the earliest data sampling file on SD card (set ON) LB-11950 : delete all data sampling files

Strona 174 - Displays

EZwarePlus Programming Manual 247 LW-9030 (32bit) : system time (unit : 0.1 second) LW-9032 (8 words) : folder name of backup history files to SD,

Strona 175

248 EZwarePlus Programming Manual LW-9150 (32 words) : keyboard's input data (ASCII) LW-9200 (16bit) : address index 0 LW-9201 (16bit) : addr

Strona 176

EZwarePlus Programming Manual 249 LW-9300 (16bit) : driver ID of local PLC 1 LW-9301 (16bit) : driver ID of local PLC 2 LW-9302 (16bit) : driver I

Strona 177

250 EZwarePlus Programming Manual LW-9552 (16bit) : COM 1 data bits (7 : 7 bits, 8 : 8 bits) LW-9553 (16bit) : COM 1 parity (0:none, 1:even, 2:odd

Strona 178

EZwarePlus Programming Manual 251 LW-9629 (16bit) : PLC 9's port no. LW-9770 (16bit) : remote printer/backup server IP0 (IP0:IP1:IP2:IP3) LW-

Strona 179

18 EZwarePlus Programming Manual Then, from the EZwarePlus Tools menu, select Build Data for USB Disk or SD Card Download. 1. Select the drive co

Strona 180 - History Data Display

252 EZwarePlus Programming Manual LW-9902 (16bit) : pass-through destination COM port (1~3 : COM 1~COM 3) LW-9905 (16bit) : remote HMI 21's I

Strona 181

EZwarePlus Programming Manual 253 LW-9953 (16bit) : remote HMI 30's IP3 (IP address = IP0:IP1:IP2:IP3) LW-9954 (16bit) : remote HMI 30'

Strona 182

254 EZwarePlus Programming Manual LW-10301 (16bit) : remote PLC 1's IP1 (IP address = IP0:IP1:IP2:IP3) LW-10302 (16bit) : remote PLC 1's

Strona 183

EZwarePlus Programming Manual 255 LW-10516 (16bit) : PLC 4 turn around delay (unit : ms) LW-10517 (16bit) : PLC 4 send ACK delay (unit : ms) (SIEM

Strona 184

How to Reach UsCorporate HeadquartersWatlow Electric Manufacturing Company12001 Lackland RoadSt. Louis, MO 63146Sales: 1-800-WATLOW2Manufacturing Supp

Strona 185 - Using Alarm/Events

EZwarePlus Programming Manual 19 Chapter 3 – Connect the HMI to the PLC or Controller The HMI5000P/L family of HMIs can connect to one, two, or mo

Strona 186

20 EZwarePlus Programming Manual Figure 2a: COM Ports for the HMI5070P, HMI5121P, and HMI5150P 1010-1015, Rev. 03

Strona 187

EZwarePlus Programming Manual 21 Figure 2b: COM Ports for the HMI5100L and HMI5070L HMI5100L HMI5070L 1010-1015, Rev. 03

Strona 188

EZwarePlus Programming Manual iii Regarding Watlow Part Numbers When you purchased your Operator Interface Terminal and accessories from Watlow, yo

Strona 189

22 EZwarePlus Programming Manual Figure 2c: COM Ports for the HMI5000HD 1010-1015, Rev. 03

Strona 190

EZwarePlus Programming Manual 23 Connecting to COM1 and COM3 on Port A Maple Systems HMI5000P/L family of HMIs is capable of connecting to multiple

Strona 191

24 EZwarePlus Programming Manual Scenario 2 – One RS485 2 Wire PLC/Controller with COM3 configured for RS485-2 Wire and one RS485 4 Wire PLC/Contro

Strona 192

EZwarePlus Programming Manual 25 Connecting to COM1 and COM3 on Port B Two RS232 PLC/Controllers, with COM1 and COM3 configured for RS232.

Strona 193

26 EZwarePlus Programming Manual Connecting multiple PLC/controllers serially using daisy chaining The RS485 4-wire and RS485 2-wire communications

Strona 194

EZwarePlus Programming Manual 27 Troubleshooting The HMI must be connected to a PLC/controller in order for the project to run correctly in the HMI

Strona 195 - Chapter 13 – Security

28 EZwarePlus Programming Manual Chapter 4 – Creating a Sample Project Often the best way to learn about new software is to jump right in and begi

Strona 196 - General Mode

EZwarePlus Programming Manual 29 2. Click New… The Select Window Style dialog box appears. 3. Click Base Window. The Window Settings dialog box

Strona 197 - Enhanced Security Mode

30 EZwarePlus Programming Manual 4. Type “Bargraph” in the Name field. The number 11 should already be in the Window No. field. 5. Click the box

Strona 198

EZwarePlus Programming Manual 31 5. Select shape number 7 and click OK. The Function Key Object’s Shape tab now shows a preview of how the functi

Strona 199

iv EZwarePlus Programming Manual This page intentionally left blank 1010-1015, Rev. 03

Strona 200

32 EZwarePlus Programming Manual 7. In the top menu bar in EZwarePlus, click Draw > Text (or select the Text Tool icon in the Draw Toolbar). I

Strona 201 - Object Security

EZwarePlus Programming Manual 33 Now let’s create a bar graph on Window 11. We will use the bar graph to indicate the level of a tank. We will cre

Strona 202 - Interlock

34 EZwarePlus Programming Manual 3. Click the Outline tab. In the Attribute section, select the following: Type: Normal Direction: Up Zero: 0 (th

Strona 203

EZwarePlus Programming Manual 35 8. Click the Picture Library… button and click the Select Lib… button. Locate tank.flb in the Library folder. Se

Strona 204 - Additional Security Features

36 EZwarePlus Programming Manual 10. Click OK to accept the properties settings. On the main screen of EZwarePlus you will see a white rectangle o

Strona 205 - Project Protection

EZwarePlus Programming Manual 37 3. In the Attribute section, select the following: Set Style: Press and hold increment (JOG++) (this will c

Strona 206 - Disable Upload Function

38 EZwarePlus Programming Manual 12. Click OK and place the Set Word Object below the bargraph on Window 11 in EZwarePlus. You can click and drag

Strona 207 - XOB Password

EZwarePlus Programming Manual 39 16. Paste the Set Word Object to the window (Edit > Paste or Ctrl+V) and drag it next to the other Set Word Ob

Strona 208 - Decompiling Prohibited

40 EZwarePlus Programming Manual 19. In the Attribute section, select the following: Set Style: Press and hold decrement (JOG--) (this will

Strona 209 - System Passwords

EZwarePlus Programming Manual 41 To create a Bit Lamp: 1. In the top menu bar in EZwarePlus, click Objects > Lamp > Bit Lamp (or select the

Strona 210

EZwarePlus Programming Manual v Table of Contents COPYRIGHT NOTICE ... ii WARRANTY ...

Strona 211

42 EZwarePlus Programming Manual 6. Click OK and place the Bit Lamp Object to the left of the tank. You can click and drag it to adjust its posit

Strona 212

EZwarePlus Programming Manual 43 10. Click the Shape tab. Click the Picture Library… button and select the Pipes Blue library (use the Select Lib…

Strona 213

44 EZwarePlus Programming Manual 3. Click the Shape tab and deselect the Use Shape checkbox. This will make the Set Bit invisible on the screen.

Strona 214 - User Accounts

EZwarePlus Programming Manual 45 4. Click OK and place the Set Bit Object on the window. It will appear as a square frame. Click on the screen to

Strona 215

46 EZwarePlus Programming Manual 3. In the File name text box, type Sample_Project.mtp. 4. Click Save. The file is saved onto your computer hard

Strona 216 - USB Security Key

EZwarePlus Programming Manual 47 3. Click and hold the arrow UP button to fill the tank. The pump turns green and the pipe starts blinking. The b

Strona 217

48 EZwarePlus Programming Manual Downloading your first project First, connect a +24 VDC power supply to the HMI. Refer to the HMI5000P/L/HD Insta

Strona 218

EZwarePlus Programming Manual 49 5. Click the Download button. If the HMI is properly connected to the PC, the status box on the download dialog w

Strona 219

50 EZwarePlus Programming Manual Chapter 5 – Simulator Mode As you saw from creating the sample project in the last chapter, downloading any chang

Strona 220

EZwarePlus Programming Manual 51 To use off-line simulation mode from EZwarePlus: 1. If the project has been modified since the last time it was

Strona 221

vi EZwarePlus Programming Manual To use on-line simulation mode from Utility Manager ...

Strona 222 - Chapter 15 – Recipes

52 EZwarePlus Programming Manual  The above method will work with a standard PC serial COM port, regardless of the COM number assigned to the PC

Strona 223

EZwarePlus Programming Manual 53 Chapter 6 – Using EZwarePlus Overview The EZwarePlus software is composed of a number of separate applications tha

Strona 224

54 EZwarePlus Programming Manual The applications are divided into groups: Design • EZwarePlus: create projects for the HMI • EasyAddressViewer:

Strona 225

EZwarePlus Programming Manual 55 Utility Easy Converter The EasyConverter application is used to view data log files (*.dtl) and event log files (*

Strona 226

56 EZwarePlus Programming Manual 2. “Event”: This column indicates the following: 0 = Event triggered; 1 = Event acknowledged; 2 = Event returns

Strona 227

EZwarePlus Programming Manual 57 Sampling Data Information: This shows the type and number of data samples contained in the data file. You can sel

Strona 228

58 EZwarePlus Programming Manual 3. Also, the raw data collected for Data 4 is a floating point number calculated to three decimal places. Howeve

Strona 229 - Chapter 16 – Operation Log

EZwarePlus Programming Manual 59 5. The data shown includes the Date (YYYY/MM/DD), Time (HH:MM:SS), Milliseconds, and the actual data for each reg

Strona 230

60 EZwarePlus Programming Manual 3. Enable Setting file: Check this box to select a conversion (*.lgs) file that performs a linear scaling convers

Strona 231 - General Tab

EZwarePlus Programming Manual 61 data being sent to the printer. Logger Bar: Displays the status of the EasyPrinter utility. Options Menu Toolba

Strona 232

EZwarePlus Programming Manual vii Using the Fast Selection Window ... 142 Using the Fast Selection Button ...

Strona 233 - Title Tab

62 EZwarePlus Programming Manual When target file has existed: When Overwrite it is checked, the existing file will be overwritten by the new file.

Strona 234 - EasyDiagnoser

EZwarePlus Programming Manual 63 2. Address range (unit: word): Use this area to select the total number of RW (recipe word) registers or EMx (Ex

Strona 235

64 EZwarePlus Programming Manual In the Data Type dialog box you can enter a description of the Data Type and select which format that the HMI will

Strona 236 - Main Window

EZwarePlus Programming Manual 65 b. Save file as *.emi for extended memory files.  You must use file names which correspond to the ten extended

Strona 237 - Polling Packages

66 EZwarePlus Programming Manual iv. Check the Recipe (RW) enable box, then select the recipe file. v. Click the Build button. A folder called ‘m

Strona 238 - Devices

EZwarePlus Programming Manual 67 Build Download Data for SD/USB Disk Data can be downloaded to the HMI5000P Series using an SD card and USB flash

Strona 239 - EasyWatch

68 EZwarePlus Programming Manual Pass-through mode The pass-through mode allows serial communications from the PC to the PLC, though the HMI. This

Strona 240

EZwarePlus Programming Manual 69 3. HMI work mode: Indicates the current mode of the HMI. After the communication parameters have been received, t

Strona 241

70 EZwarePlus Programming Manual 1. Click Install to install the virtual COM port driver. The Virtual COM Port (PC <-> PLC) indicates the vi

Strona 242

EZwarePlus Programming Manual 71 EZwarePlus Features This section guides you in a basic understanding of the features and capabilities that EZwareP

Strona 243

viii EZwarePlus Programming Manual Output ... 230 Logger ...

Strona 244

72 EZwarePlus Programming Manual Set Bit The Set Bit Object is used as a button to toggle ON or OFF the state of a bit or coil in the PLC, or a b

Strona 245

EZwarePlus Programming Manual 73 Slider Object The Slider Object is used as a control to change the value in a PLC register, or the value in a re

Strona 246

74 EZwarePlus Programming Manual Direct Window The Direct Window Object is used to display a window based on the state of a bit in a register (sp

Strona 247

EZwarePlus Programming Manual 75 Video In The Video In Object is used to input and play video on the HMI from an external source. One of two vide

Strona 248

76 EZwarePlus Programming Manual A control function can be enabled that allows the value in a PLC register to control the video input. Control Wor

Strona 249

EZwarePlus Programming Manual 77 History Data Display The History Data Display Object is used to display historical data collected by the Data Sa

Strona 250 - Reserved Local Bits

78 EZwarePlus Programming Manual The number of data points must be stored at [control word address + 1], and the data must be stored starting at [D

Strona 251

EZwarePlus Programming Manual 79 The Read address field is the starting address of the data to plot. Each channel has its own Read address. Normall

Strona 252

80 EZwarePlus Programming Manual Line: The data is plotted as a Line graph, with squares plotted at each data point. Point: The data is plotted as

Strona 253

EZwarePlus Programming Manual 81 In History mode, alarm/events from previous days can be displayed. The Write address changes to History Control ad

Strona 254 - Reserved Local Words

EZwarePlus Programming Manual 1 Chapter 1 – Introduction Welcome Welcome to the Maple Systems’ Silver Series EM Operator Interface Terminals (OITs)

Strona 255

82 EZwarePlus Programming Manual The WATCH addresses can be used to display the data in up to four registers in messages. Click the Syntax button t

Strona 256

EZwarePlus Programming Manual 83 Change Window This causes the HMI to close the currently-displayed Base Window, and display the Base Window whose

Strona 257

84 EZwarePlus Programming Manual Sound Control Plays the selected sound when the bit specified by the Trigger address matches the trigger mode cond

Strona 258

EZwarePlus Programming Manual 85 starting address of the data samples and the Data Record area allows you to configure how many consecutive registe

Strona 259

86 EZwarePlus Programming Manual Click the Time Set tab to configure the start and end times for the scheduled action. When Constant is selected, t

Strona 260

EZwarePlus Programming Manual 87 Drawing Tools Includes Line, Arbitrary Line, Link Line, Arc, Ellipse/Circle, Pie, Rectangle, Polygon, Scale, Tex

Strona 261

88 EZwarePlus Programming Manual 2. If changes have been made to the project file, EZwarePlus will ask you if you would like to save the project.

Strona 262

EZwarePlus Programming Manual 89 2. In the Compress box under Source Name, select the project (*.mtp) file that you wish to compress. The file mus

Strona 263

90 EZwarePlus Programming Manual 2. The Object List combines a list of all of the windows in a project, and all of the objects on each window, i

Strona 264 - SATISFACTION

EZwarePlus Programming Manual 91 3. To display an open window, click on the window number in the Window Tree. To display a window that is not ye

Komentarze do niniejszej Instrukcji