Watlow EZ-ZONE RM Limit Module Rev C Instrukcja Użytkownika Strona 104

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 127
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 103
Watlow EZ-ZONE
®
RML Module 101 Chapter 6 Features
Math
Differential
Range Low
Range High
Pressure Units
Altitude Units
Scale Low
Scale High
Function
Filter
Offset
Filter
Output Value = Filter [(A - B) + Offset]
Display units follows Source A plus
relative Source B
Source Function A
Source Instance A
Source Zone A
Source Error A
Source Function B
Source Instance B
Source Zone B
Source Error B
Source Function C
Source Instance C
Source Zone C
Source Error C
Source Function D
Source Instance D
Source Zone D
Source Error D
Source Function E
Source Instance E
Source Zone E
Source Error E
Source Value A
Source Value B
Source Value C
Source Value D
Source Value E
Output Value
Error
Math
Add
Range Low
Range High
Pressure Units
Altitude Units
Scale Low
Scale High
Function
Filter
Offset
Filter
Output Value = Filter [(A + B + C + D) +
Offset] Display units follows last
temperature source else follow Source A
Source Function A
Source Instance A
Source Zone A
Source Error A
Source Function B
Source Instance B
Source Zone B
Source Error B
Source Function C
Source Instance C
Source Zone C
Source Error C
Source Function D
Source Instance D
Source Zone D
Source Error D
Source Function E
Source Instance E
Source Zone E
Source Error E
Source Value A
Source Value B
Source Value C
Source Value D
Source Value E
Output Value
Error
Math
Multiply
Range Low
Range High
Pressure Units
Altitude Units
Scale Low
Scale High
Function
Filter
Offset
Filter
Output Value = Filter [(A * B * C * D) +
Offset] Display units follows last
temperature source else follow Source A
Source Function A
Source Instance A
Source Zone A
Source Error A
Source Function B
Source Instance B
Source Zone B
Source Error B
Source Function C
Source Instance C
Source Zone C
Source Error C
Source Function D
Source Instance D
Source Zone D
Source Error D
Source Function E
Source Instance E
Source Zone E
Source Error E
Source Value A
Source Value B
Source Value C
Source Value D
Source Value E
Output Value
Error
Math
Minimum
Range Low
Range High
Pressure Units
Altitude Units
Scale Low
Scale High
Function
Filter
Offset
Filter
Output Value = Filter [Minimum Value
(A : B : C : D) + Offset] Display units
follows Source with minimum value.
Source Function A
Source Instance A
Source Zone A
Source Error A
Source Function B
Source Instance B
Source Zone B
Source Error B
Source Function C
Source Instance C
Source Zone C
Source Error C
Source Function D
Source Instance D
Source Zone D
Source Error D
Source Function E
Source Instance E
Source Zone E
Source Error E
Source Value A
Source Value B
Source Value C
Source Value D
Source Value E
Output Value
Error